Re: Using variants in subject line of BW Process Chain
Hello George, After creating the variant for message, go to Edit Document and give the system name and its details under Title as below. It will be the subject for notification email.
View ArticleMigrate CMOD to BADI
Hi All, we are trying to migrate ECC CMOD logic to BADI (RSU5_SAPI_BADI). in ECC CMOD we have two enhancements RSAP0001 -Customer function calls in the service API & MCS10001 -SIS: Statistics...
View ArticleBW 7.4 SP10 Upgrade
Team, We are planning to upgrade our BW 7.0 to BW 7.4 and our source is ECC 6.0 with no EPh. Please advise if there will be any issue with the source. Thanks,Saleem.
View ArticleRe: Migrate CMOD to BADI
Hi Manoj, BAdI RSU5_SAPI_BADI can only replace Enhancement RSAP0001. Although they are using different technology, they are equal to each other in terms of functionality and purpose: DataSource...
View ArticleRe: How to run bw process chain with dialog parameter
Hello, Try with ABAP program . Read the file and run the process chain through function module. Function module to run the process chain: CALL FUNCTION 'RSPC_CHAIN_START_SYNCHRONOUS' EXPORTING...
View ArticleRe: BW 7.4 SP10 Upgrade
Hi Saleem, You do not have to expect any issues with an SAP ECC 6.0 system. Best regards,Sander
View ArticleRe: Migrate CMOD to BADI
Thanks Sander for reply. Does that mean even though i move enhancement RSAP0001 to BADI , i am not supposed to deactivate CMOD due to MCS10001 ? Is there any BADI available for enhancement MCS10001?...
View ArticleRe: Migrate CMOD to BADI
Hi Manoj, I think that you mean with "deactivate CMOD" to deactivate the Project. That you should not do since it will also deactivate Enhancement MCS10001. I got the impression that both Enhancement...
View ArticleRe: BW 7.4 SP10 Upgrade
Hello Saleem, Please check following SAP note attachment.it consists of compatibility versions. 1388258 - Version Interoperability within the SAP Business Suite BW 7.40 with ERP 6.0 without EHP. You...
View ArticleRe: BW 7.4 SP10 Upgrade
Hi Anand, Thanks for sharing the additional information.The Upgrade Dependency Analyzer does not indicate any dependency. Please see also the screenshot. However, in case of any doubt please check...
View ArticleRe: BW 7.4 SP10 Upgrade
Sander/Anand,I did checked the UDA and does not indicate any dependency . Thank you both for your advise.Thanks,Saleem.
View ArticleRe: How to run bw process chain with dialog parameter
Hi, As Sander said please explain clearly your requirement..What's that value in BW characteristic? You mean an event or something that must be satisfied? Regards,Loed
View ArticleRe: How to get used InfoPackage name in SAP BW 3.5 in update/ start routine?
Although it's late to answer this question maybe somebody will find it helpful. One can get the id request in progress and corresponding infopackage technical name using the next code: DATA: lv_pck...
View ArticleRe: No SID found for 0UNIT reference cahracteristics
Hi All, It does not worked for me .. still same error ... please help .. Regards,Prasanth.M
View ArticleRe: How to run bw process chain with dialog parameter
Hi, Here is some more info:1. Information comes to BW from many csv-files by packages.2. One package consists of 50+ files from one company (BW Characteristic).3. Each file name looks like...
View ArticleIs it possible to use Timestamp as an numeric pointer is well?
Hi Team, I've one of the flow which was designed earlier, when i was not in the part of team, Now for some reason, the data is not matching in reports as required by users. for that reason i started...
View ArticleRe: Is it possible to use Timestamp as an numeric pointer is well?
Hi, A Time Stamp field in combination with Numeric Pointer seems to me an illogical design choice. I also wonder how it works with the Safety Interval Lower Limit. The Safety Interval Limits' unit of...
View ArticleRe: Is it possible to use Timestamp as an numeric pointer is well?
Hi Willigen, Thanks a lot for your reply, which helps in current analysis. Is there any chance can we take the 'Timestamp' Field in related to the user posting time based on the delta mechanism of...
View Article